1. Fiber transmission laser with laser power real-time feedback control system, exclude laser energy instability phenomenon caused by power grid fluctuation, temperature change and xenon lamp aging and improved uniformity of welding products.
2. Combined laser power detection device based on preset laser waveform with real-time closed-loop control of laser power supply
3. Automatically stabilizing laser energy
Laser model | WCF80 | WCF150 | WF350 | WF600 |
Laser type | YAG | YAG | YAG | YAG |
Laser wavelength | 1064nm | 1064nm | 1064nm | 1064nm |
Laser output average power | 80W | 150W | 300W | 600W |
Max. laser peak power | 5kW | 6kW | 6kW | 9Kw (12kW optional) |
Max. laser pulse energy | 30J | 30J | 30J (standard) | 50J/ (90J optional) |
60J/90J (optional) | ||||
Pulse width | ≤50ms | ≤50ms | ≤50ms | ≤50ms |
Pulse frequency | ≤100Hz | ≤200Hz | ≤200Hz | ≤200Hz |
Waveform number | 50 groups | 50 groups | 50 groups | 50 groups |
Fiber transmission number | 2 paths | 2 path | 2 paths standard, 4 paths at most | 1 path standard, 4 paths at most |
Beam split mode | Time splitting | Time splitting | High speed beam split | Energy splitting or time splitting |
Fiber core diameter | 0.4mm | 0.6mm | 0.6mm (standard) 0.3/0.4mm optional | 0.6mm |
Closed-loop feedback control mode | Laser power feedback | Laser power feedback | Laser power feedback | Laser power feedback |
Aiming positioning mode | Red light guide (CCD optional) | Red light guide (CCD optional) | Red light guide (CCD optional) | Red light guide (CCD optional) |
Cooling mode | Internal air cooling | Internal air cooling (external water cooling optional) | External water cooling | External water cooling |
Main machine power consumption | 5kW | 7kW | 16.5kW | 20kW |
Power demand (voltage, frequency and current) | 220V±10%/50Hz 25A | 380V±10%/50Hz 32A | 380V±10%/50Hz 40A | 380V±10%/50Hz 42A |
Main machine weight | 350kg | 350kg | 450kg | 500kg |
Main machine dimension (L*W*H) | 1280x550x1165mm | 1280x550x1165mm | 1480x610x1100mm | 1518x700x1180mm |
Water chiller rated power | —— | —— | 3.5kW | 9.7kW |
Water chiller cooling capacity | —— | —— | 7.5Kw (12.5kW optional) | 17.5kW |
Water chiller power demand | —— | —— | 220V±10% 50Hz 16.5A | 380V±10%/50Hz 17A |
Water chiller dimension (L*W*H) | —— | —— | 850x550x1158mm | 1156x800x1430mm |